' Script: check_etrust_av.vbs
' Author: Matt White
' Version: 1.0
' Date: 12-03-2010
' Details: Check the current definitions for E-Trust AntiVirus are within acceptable bounds
' Usage: cscript /nologo check_etrust_av.vbs -w: -c:

' Define Constants for the script exiting
Const intOK = 0
Const intWarning = 1
Const intCritical = 2
Const intUnknown = 3

' Parse Arguments to find Warning and Critical Levels
If Wscript.Arguments.Named.Exists("w") Then
  intWarnLevel = Cint(Wscript.Arguments.Named("w"))
Else
  intWarnLevel = 2
End If

If Wscript.Arguments.Named.Exists("c") Then
  intCritLevel = Cint(Wscript.Arguments.Named("c"))
Else
  intCritLevel = 4
End If

' Define Date Regular Expression
Const strDateRegExp = "(0[1-9]|1[012])[- /.](0[1-9]|[12][0-9]|3[01])[- /.](19|20)dd"

' Create required objects
Set objShell = CreateObject("Wscript.Shell")
Set ObjProcess = ObjShell.Environment("Process")
Set objRegExp = New RegExp
Set objReg=GetObject("winmgmts:{impersonationLevel=impersonate}!\.rootdefault:StdRegProv")

const HKEY_CURRENT_USER = &H80000001
const HKEY_LOCAL_MACHINE = &H80000002


' read the path of E-Trust Anti-Virus from the registry
strKeyPath = "SOFTWAREComputerAssociatesScanEnginePath"
objReg.GetStringValue HKEY_LOCAL_MACHINE,strKeyPath,"Engine",strScanEnginePath

If TypeName(StrScanEnginePath) = "Null" Then
  WScript.Echo "UKNOWN: Cannot read registry Info. Is E-Trust installed?"
  Wscript.Quit(intUnknown)
End If

'strScanEnginePath = ObjShell.RegRead("HKLMSOFTWAREComputerAssociatesScanEnginePathEngine")

' Determine CPU architecture for correct executable to run
strCPUArch = objProcess("PROCESSOR_ARCHITECTURE")
If InStr(1, strCPUArch, "x86") > 0 Then
strExecutable = "inocmd32.exe"
ElseIf InStr(1, strCPUArch, "64") > 0 Then
strExecutable = "inocmd64.exe"
End If


' If the path doesnt exist Exit with an Unknown status
If Len(StrScanEnginePath) = 0 Then
  Wscript.Echo "UNKNOWN: Unable to read registry path"
  Wscript.Quit(intUnknown)
End If

' Run the command and read the output into a string
Set objExec = objShell.Exec(strScanEnginePath & strExecutable & " /sig")
strVirusDefs = objExec.StdOut.ReadAll()

' Search the Virus definition for the date using Regular Expression
objRegExp.Pattern = strDateRegExp
objRegExp.Global = True
objRegExp.IgnoreCase = True
Set regExpMatch = objRegExp.Execute(strVirusDefs)

' If date not found in the output. Exit with a warning
If regExpMatch.Count = 0 Then
  Wscript.Echo "UNKNOWN: Unable to read date from the output"
  Wscript.Quit(intUnknown)
End If

intDateDifference = DateDiff("d",CDate(regExpMatch(0).Value), Date)

Wscript.Echo strVirusDefs
If intDateDifference > intCritLevel Then
  Wscript.Quit(intCritical)
ElseIf intDateDifference > intWarnLevel Then
  Wscript.Quit(intWarning)
ElseIf intDateDifference <= intWarnLevel Then
  Wscript.Quit(intOK)
End If
Wscript.Quit(intUnknown)